BUSY_FRACTIONS_FILE_NAME#
If SAVE_OUTPUT=True
, a CSV file is generated where each row represents the empirical busy fraction of one simulation run. The file is named according to the variable BUSY_FRACTIONS_FILE_NAME
. The busy fraction is a value between 0 and 1, where 1 indicates that the ambulances are busy full-time. A warm-up and cool-down period is used for the calculation of the busy fraction. These can be determined by the parameters AT_BOUNDARY
(warm-up) and FT_BOUNDARY
(cool-down). In the example below, the busy fraction of the first run is 0.390, of the second run 0.445 and of the third run 0.312.
0 |
|
---|---|
0 |
0.390 |
1 |
0.445 |
2 |
0.312 |